Bölge seçiniz
Gönder

Flow-c Anesthesia Machine

Our compact anesthesia model

Flow-c is the easy-to-use dynamic anesthesia machine. Despite its small size, it offers all Flow Family innovations, making sure to cover the need of care efficiency.

That in combination with its compact design gives it an advantage in the crowded Operating Room in a hospital as well as Ambulatory Surgery Centers, all with a busy schedule.

Dynamic Anesthesia Delivery when Every. Breath. Counts. 

 

Getinge Flow-c is our compact, easy-to-use anesthesia machine for the busy OR
Getinge’s compact anesthesia machine Flow-c has 215 cm multipurpose rails for mount monitors, tables and accessories.
Our compact anesthesia machine, Getinge Flow-c , offers cable management without clutter designed for the crowded OR

Compact efficiency in the busy OR

Flow-c is our compact anesthesia machine enabling safe and cost-efficient treatment.

  • ICU-grade ventilation performance
  • Safe and easy low-flow anesthesia
  • MAC Brain for informed anesthetic dosing decisions
  • Active hypoxia prevention with O2Guard
  • Lung Recruitment Maneuvers to prevent postoperative complications

User-friendly workstation in the OR

 

Large drawer

With slots for spare vaporizers and an optional lockable compartment.

 

Cable management

Hoses and cables are neatly routed and covered by specially designed panels, contributing to improved hygiene and safety.

 

215 cm rails for flexible mounting

Despite its compact size, Flow-c has 215 cm multipurpose rails! Mount monitors, tables and accessories where it best suits you.

Yasal Uyarı

Ürünler, Flow Ailesi anestezi sistemlerinin mevcudiyeti ve SW versiyonu ülkenizde pazarlanmak üzere düzenleyici onayları bekliyor olabilir. Daha fazla bilgi için Getinge temsilcinizle görüşün. Hekim tarafından belirtilen iddialar kesinlikle hekime aittir ve Getinge'nin görüşlerini yansıtmayabilir.
Yasal Üretici · Maquet Critical Care AB · Röntgenvägen 2 SE-171 54 Solna · İsveç · +46 (0)10 335 73 00

Our unique anesthesia technology makes the difference

AGC Anesthesia Flow

Automatic Gas Control (AGC)

Safe and easy low-flow anesthesia

Automatic Gas Control (AGC) makes low-flow anesthesia delivery safe. Automation eliminates the need of continuous manual adjustments: with simple pre-settings, specifying the targeted inspired oxygen, end-tidal anesthetic agent levels and required speed, AGC solves the rest. Our innovation offers high precision combined with improved comfort and increased safety. [1] [2] [3] [4] [5] [6]

o2guard anesthesia flow

O₂Guard

Active hypoxia prevention

Our O2Guard is the world’s only system for active hypoxia prevention. Should the inspired oxygen level drop below 21%, the O2Guard automatically overrules the settings and increases the flow of oxygen. [7]

Mac brain anesthesia flow

MAC Brain

Informed anesthetic dosing

To facilitate decision-making when planning and dosing anasthesia agents, we created MAC Brain. Using mathematical models and data-driven algorithms, MAC Brain visualizes the difference in agent effect in the lungs and the brain - actings as a decision-support framework to help guide anesthetic dosing.[8]

Lung recruitment flow anesthesia

Lung recruitment

Gentle steps against atelectasis

Our lung recruitment maneuvers have become the tool of choice to counter
atelectasis, to improve oxygenation and help prevent postoperative complications. [9] [10]

Ventilation anesthesia flow

Ventilation performance

Offering ICU-grade ventilation

Innovative Flow Core Technology is designed to promote efficient agent usage, providing the power and precision to ventilate even challenging patients. [11] [12]

User-friendly workstation in the OR

Developed together with clinicians, the compact Flow-c anesthesia machine is designed to facilitate a great scope for configuration and patient safety. With an intuitive interface and emphasis on ease of use [16], our anesthesia solutions ensure a streamlined workflow and efficiency in the operating room that offers enhanced cost control and resource management.

Our anesthesia workstation

Our anesthesia workstation

1. Open platform

Customize to match your needs

2. Convenient USB and light

USB ports for data transfer and power supply are easily accessible. Three step dimmable LED lights up the workspace.

3. Intuitive and flexible control panel

The flexible and intuitive touch screen gives you one point of control for all functions. 15” tiltable and rotatable touch screen.

Watch the video
4. 215 cm multipurpose rails

Extensive and flexible mounting options

5. Auxiliary O2 and suction
6. Water trap

Visible and accessible

7. Snap on hooks

For convenient placement of tubes, manual breathing bags, suction tips and other accessories.

8. Large and flexibel workspaces

Practical for your everyday needs

9. CO2 absorber

Easy to change

10. Electronic vaporizer

Precise and cost-efficient

11. Smart cable and hose management

Less clutter, easier cleaning and improved mobility

12. Large drawer

With slots for spare vaporizers and an optional lockable compartment.

Watch the video
13. Central 4-wheel brake

Brake and cable pushers. Enhances device mobility.

Kapsamlı Servis ve Destek

 

Prosedürleri iptal etmekten kaçının

Bağlanın ve kontrolü elinize alın

Getinge Online web portalı sizi herhangi bir Getinge cihazına bağlayarak biyomedikal ve klinisyenleri günlük işlerinde destekleyecek değerli verilere erişim sağlar. Portal, hastane kaynaklarınızın çalışma süresini ve verimli kullanımını artırmak için güçlü bir araçtır. 

  • Ameliyathanenizde çalışma süresini artırın
  • Maliyetleri ve karbon ayak izini azaltın
Man looking straight smiling

Tutarlı bir teklif

Getinge Hizmetleri, çalışma süresini ve yatırımınızın uzun vadeli değerini en üst düzeye çıkaracaktır. Sertifikalı saha temsilcilerimiz tarafından proaktif bakım, kolay sorun giderme ve hızlı servis içeren bir servis planı sunuyoruz - ekipmanınızın her zaman tam potansiyeliyle çalışmasını sağlıyoruz.

Anesthesia consumables

Kaliteli sarf malzemeleri

Orijinal Getinge sarf malzemeleri portföyü, mümkün olan en yüksek hasta güvenliği ve kullanım kolaylığı için özel olarak geliştirilmiştir. Orijinal aksesuarlarımız ve sarf malzemelerimiz, Flow Ailesi anestezi uygulama sistemi için en iyi performansı ve güvenliği sağlar.

MSync

Cihazlar arasındaki bağlanabilirlik

MSync, Flow makinesini üçüncü taraf sisteme ihtiyaç duymadan hasta monitörü, HIS ve hasta veri yönetim sistemine bağlamayı kolaylaştırır. Hasta verileri, karar vermeyi desteklemek için gerçek zamanlı olarak HL7 (MSync) aracılığıyla aktarılır.

Visit our Academy – training and education designed to enhance your proficiency

For more information about our onsite events or remote trainings, you can also contact your local sales & service representative.

  1. 1. Carette R, De Wolf AM, Hendrickx JF. Automated gas control with the Maquet Flow-i. J Clin Monit Comput. 2016 Jun;30(3):341-6.

  2. 2. Moran P, Barr, D, Holmes, C, Saving sevoflurane: Automatic gas control can reduce
    consumption of anesthetic vapor by one-third in pediatric anesthesia.Paediatric
    Anaesthesia. 2019 Apr; 29(4):310-314.

  3. 3. Yusuf Z. Colak & Hüseyin I. Toprak. Feasibility, safety, and economic consequences of using minimal flow anaesthesia by Maquet FLOW‑i equipped with automated gas control. Scientific Reports (2021) 11:20074.

  4. 4. De Medts R, Carette R, De Wolf A, Hendrickx J. Desflurane usage during anesthesia with and without N2O using FLOW-i Automatic Gas Control with three different wash-in speeds. J Clin Monit Comput (2018) 32:763–769.

  5. 5. D. Mostad, P Klepstad, T Follestad & H Pleym, Desflurane consumption with
    automated vapour control systems in two different anaesthesia machines. A randomized controlled study. Acta Anaesthesiol Scandinavica. 2021 Aug;65 (7):895-901.

  6. 6. Kalmar A. et al. Minimizing sevoflurane wastage by sensible use of automated gas control technology in the flow-i workstation: an economic and ecological assessment. J Clin Monit Comput. 2022 Jan 3. doi: 10.1007/s10877-021-00803-z

  7. 7. Hendrickx J, Ghijselings IE, De Cooman S, Carette R, et al. Performance of an active inspired hypoxic guard. J Clin Monit Comput. 2016 Feb;30(1):63-68.

  8. 8. ECRI. The MAC Brain feature on Getinge anesthesia units: ECRI's view. Device Evaluation 2022 Jan5.

  9. 9. García-Fernández J, Romero A, Blanco A, et al. Recruitment manoeuvres in anaesthesia: How many more excuses are there not to use them? Rev Esp Anestesiol Reanim.2018 Apr;65(4):209-217

  10. 10. Yassen et al. Respiratory and Hemodynamic Effects of Prophylactic Alveolar Recruitment During Liver Transplant. Experimental and Clinical Transplantation (2021) DOı: 10.6002/ect.2020.0412

  11. 11. Internal test reports comparing Flow-i with vendor machines

  12. 12. Case study contributed by Dr. Waltraud Bruchelt and Dr. Günter Baumann, Dept. of Anaesthesiology and Intensive Care Medicine, University Hospital Graz, Austria.

  13. 13. Internal report NPS Summary Anesthesia 2019