Seleziona la regione
Invia

Macchina per anestesia Flow-c

Il nostro modello per anestesia compatto

Flow-c è la macchina per anestesia dinamica facile da usare. Nonostante le sue dimensioni compatte, offre tutte le innovazioni della gamma di prodotti Flow, assicurandosi di coprire le esigenze di efficienza assistenziale.

Questo, unito al suo design compatto, offre un vantaggio nelle sala operatorie affollate degli ospedali e dei centri di chirurgia ambulatoriale.

Erogazione dinamica dell'anestesia quando Ogni Respiro. Conta. 

 

Getinge Flow-c is our compact, easy-to-use anesthesia machine for the busy OR
Getinge’s compact anesthesia machine Flow-c has 215 cm multipurpose rails for mount monitors, tables and accessories.
Our compact anesthesia machine, Getinge Flow-c , offers cable management without clutter designed for the crowded OR

Efficienza compatta nella sala operatoria trafficata

Flow-c è la nostra macchina per anestesia compatta che consente un trattamento sicuro e conveniente.

  • Prestazioni ventilatorie conformi agli standard ICU
  • Anestesia a bassi flussi sicura con Automatic Gas Control
  • MAC Brain per un migliore controllo della profondità dell'anestesia
  • Prevenzione attiva dell'ipossia con O2Guard
  • Manovre di reclutamento polmonare per prevenire complicanze postoperatorie

La nostra esclusiva tecnologia per anestesia fa la differenza

 

Anestesia a bassi flussi semplice e sicura

Automatic Gas Control (AGC) rende sicura l'erogazione dell'anestesia a bassi flussi. Con semplici pre-impostazioni, che specificano l'ossigeno inspirato target, i livelli di agente anestetico di fine espirazione e la velocità richiesta, AGC risolve il problema. La nostra innovazione offre un'elevata precisione unita a comfort e sicurezza maggiori. [1][2][3][4][5][6]

 

Miglior dosaggio dell'agente anestetico

Per ottenere un controllo più preciso della profondità dell'anestesia abbiamo creato MAC Brain. Si tratta di uno strumento unico che visualizza la differenza nella concentrazione dell'agente tra i polmoni e l'organo target, il cervello. L'affidabilità dei dati vi dà il controllo, consentendovi di pianificare e fornire un dosaggio più efficiente degli agenti con sicurezza e facilità. [8][9][10]

Stazione di lavoro intuitiva nella sala operatoria

 

Ampio cassetto

Dotato di slot per i vaporizzatori di ricambio e, su richiesta, di uno scomparto con serratura.

 

Gestione cavi

Tubi e cavi vengono ordinatamente guidati all'interno e coperti da appositi pannelli, migliorando il livello di igiene e sicurezza.

 

Barre normalizzate da 215 cm per un montaggio flessibile

Nonostante le dimensioni compatte, Flow-c dispone di barre normalizzate multifunzione da ben 215 cm! Potrete quindi installare monitor, tavolini e accessori dove più vi occorre.

Clausola di esclusione della responsabilità

I prodotti, la disponibilità dei sistemi per anestesia della gamma Flow e la versione del SW potrebbero essere in fase di approvazione delle autorità competenti per la commercializzazione nel Paese di riferimento. Contattare il rappresentante Getinge per maggiori informazioni. Le dichiarazioni rilasciate dal clinico sono da ritenersi strettamente personali e non rappresentano necessariamente il punto di vista di Getinge .
Produttore legale · Maquet Critical Care AB · Röntgenvägen 2 SE-171 54 Solna · Svezia · +46 (0)10 335 73 00

La nostra esclusiva tecnologia per anestesia fa la differenza

AGC Anesthesia Flow

Automatic Gas Control (AGC)

Anestesia a bassi flussi semplice e sicura

Automatic Gas Control (AGC) rende sicura l'erogazione dell'anestesia a bassi flussi. Questa opzione è disponibile esclusivamente con le macchine Flow-i. L'automazione elimina la necessità di regolazioni manuali continue: con semplici pre-impostazioni, che specificano l'ossigeno inspirato target, i livelli di agente anestetico di fine espirazione e la velocità richiesta, AGC risolve il problema. La nostra innovazione offre un'elevata precisione unita a comfort e sicurezza maggiori. [1] [2] [3] [4] [5] [6]

o2guard anesthesia flow

O₂Guard

Prevenzione attiva dell'ipossia

Il nostro O2Guard è l'unico sistema al mondo per la prevenzione attiva dell'ipossia. Se il livello di ossigeno inspirato scende al di sotto del 21%, O2Guard esclude automaticamente le impostazioni e aumenta il flusso di ossigeno. [7]

Mac brain anesthesia flow

MAC Brain

Miglior dosaggio dell'agente anestetico

Per ottenere un controllo più preciso della profondità dell'anestesia abbiamo creato MAC Brain. Si tratta di uno strumento unico che visualizza la differenza nella concentrazione dell'agente tra i polmoni e l'organo target, il cervello. [8] [9] [10]

Lung recruitment flow anesthesia

Reclutamento polmonare

Passi delicati contro l'atelettasia

Le nostre manovre di reclutamento polmonare sono diventate lo strumento d'eccellenza per combattere
l'atelettasia, migliorare l'ossigenazione e aiutare a prevenire complicanze postoperatorie. [11] [12]

Ventilation anesthesia flow

Prestazioni ventilatorie

Agli standard di terapia intensiva

L'innovativa tecnologia Flow Core è progettata per promuovere un utilizzo dell'agente efficiente, fornendo la potenza e la precisione necessarie per ventilare anche i pazienti più critici. [13] [14] [15]

Stazione di lavoro intuitiva nella sala operatoria

Sviluppata in collaborazione con i medici, la compatta macchina per anestesia Flow-c è progettata per facilitare la configurazione e la sicurezza del paziente. Grazie all'interfaccia intuitiva e alla facilità d'uso16, le nostre soluzioni per anestesia garantiscono un flusso di lavoro semplificato e maggiore efficienza nella sala operatoria con conseguenti miglioramenti nel controllo dei costi e nella gestione delle risorse.

Our anesthesia workstation

Our anesthesia workstation

1. Open platform

Customize to match your needs

2. Convenient USB and light

USB ports for data transfer and power supply are easily accessible. Three step dimmable LED lights up the workspace.

3. Intuitive and flexible control panel

The flexible and intuitive touch screen gives you one point of control for all functions. 15” tiltable and rotatable touch screen.

Watch the video
4. 215 cm multipurpose rails

Extensive and flexible mounting options

5. Auxiliary O2 and suction
6. Water trap

Visible and accessible

7. Snap on hooks

For convenient placement of tubes, manual breathing bags, suction tips and other accessories.

8. Large and flexibel workspaces

Practical for your everyday needs

9. CO2 absorber

Easy to change

10. Electronic vaporizer

Precise and cost-efficient

11. Smart cable and hose management

Less clutter, easier cleaning and improved mobility

12. Large drawer

With slots for spare vaporizers and an optional lockable compartment.

Watch the video
13. Central 4-wheel brake

Brake and cable pushers. Enhances device mobility.

Assistenza e supporto inclusi

 

Evitare procedure di cancellazione

Connettersi e assumere il controllo

Il portale web Getinge Online vi collega a qualsiasi dispositivo Getinge, garantendovi l'accesso a dati preziosi che supporteranno biomedici e medici nel loro lavoro quotidiano. Il portale è uno strumento potente per migliorare i tempi di attività e l'uso efficiente delle risorse ospedaliere. 

  • Migliorare l'efficienza in sala operatoria
  • Ridurre i costi e l'impronta di carbonio
Man looking straight smiling

Un'offerta coerente

I servizi di Getinge ottimizzano l'operatività e il valore a lungo termine del vostro investimento. Forniamo un piano di assistenza che include una manutenzione proattiva, una semplice risoluzione dei problemi e un'assistenza tempestiva da parte dei nostri rappresentanti certificati sul campo, per garantire che le vostre apparecchiature funzionino sempre al meglio.

Anesthesia consumables

Materiali di consumo di qualità

Il portfolio di materiali di consumo originali Getinge è stato sviluppato appositamente per garantire la massima sicurezza del paziente e la massima facilità d'uso. I nostri accessori e materiali di consumo originali garantiscono le migliori prestazioni e la massima sicurezza per il sistema di erogazione di anestesia della Flow Family.

MSync

Connettività tra sistemi

MSync semplifica il collegamento della macchina Flow al monitor paziente, all'HIS e al sistema di gestione dei dati paziente senza la necessità di sistemi di terze parti. I dati del paziente vengono trasferiti tramite protocollo HL7 (MSync) in tempo reale, permettendo una risposta tempestiva.

  • The Flow Family machines are designed for ease of use and a streamlined workflow, with our innovative technology contributing to enhanced patient safety and improved care outcomes. Every. Breath. Counts.

Approfondite le vostre conoscenze con i nostri corsi di formazione ed eLearning

Per ulteriori informazioni sui nostri eventi in loco o sui corsi di formazione da remoto, potete anche contattare il vostro rappresentante locale di vendita e assistenza.

  1. 1. Carette R, De Wolf AM, Hendrickx JF. Automated gas control with the Maquet Flow-i. J Clin Monit Comput. 2016 Jun;30(3):341-6.

  2. 2. Moran P, Barr, D, Holmes, C, Saving sevoflurane: Automatic gas control can reduce
    consumption of anesthetic vapor by one-third in pediatric anesthesia.Paediatric
    Anaesthesia. 2019 Apr; 29(4):310-314.

  3. 3. Yusuf Z. Colak & Hüseyin I. Toprak. Feasibility, safety, and economic consequences of using minimal flow anaesthesia by Maquet FLOW‑i equipped with automated gas control. Scientific Reports (2021) 11:20074.

  4. 4. De Medts R, Carette R, De Wolf A, Hendrickx J. Desflurane usage during anesthesia with and without N2O using FLOW-i Automatic Gas Control with three different wash-in speeds. J Clin Monit Comput (2018) 32:763–769.

  5. 5. D. Mostad, P Klepstad, T Follestad & H Pleym, Desflurane consumption with
    automated vapour control systems in two different anaesthesia machines. A randomized controlled study. Acta Anaesthesiol Scandinavica. 2021 Aug;65 (7):895-901.

  6. 6. Kalmar A. et al. Minimizing sevoflurane wastage by sensible use of automated gas control technology in the flow-i workstation: an economic and ecological assessment. J Clin Monit Comput. 2022 Jan 3. doi: 10.1007/s10877-021-00803-z

  7. 7. Hendrickx J, Ghijselings IE, De Cooman S, Carette R, et al. Performance of an active inspired hypoxic guard. J Clin Monit Comput. 2016 Feb;30(1):63-68.

  8. 8. Drews FA, Syroid N, Agutter J, Strayer DL, Westenskow DR. Drug delivery as control task: improving performance in common anesthetic task. Hum Factors 2006;48:85–94.

  9. 9. ECRI. The MAC Brain feature on Getinge anesthesia units: ECRI's view. Device Evaluation 2022 Jan5.

  10. 10. Internal report EVU-197031 - 01 - Flow 4.7 Enhanced Post Market Surveillance Report 2019

  11. 11. García-Fernández J, Romero A, Blanco A, et al. Recruitment manoeuvres in anaesthesia: How many more excuses are there not to use them? Rev Esp Anestesiol Reanim.2018 Apr;65(4):209-217

  12. 12. Yassen et al. Respiratory and Hemodynamic Effects of Prophylactic Alveolar Recruitment During Liver Transplant. Experimental and Clinical Transplantation (2021) DOı: 10.6002/ect.2020.0412

  13. 13. Internal test reports comparing Flow-i with vendor machines

  14. 14. Case study contributed by Dr. Waltraud Bruchelt and Dr. Günter Baumann, Dept. of Anaesthesiology and Intensive Care Medicine, University Hospital Graz, Austria.

  15. 15. Lucangelo U, Ajčević M, Accardo A, et al. Flow-i ventilator performance in the presence of a circle system leak. J Clin Monit Comput. 2017 Apr;31(2):273 280.

  16. 16. Internal report NPS Summary Anesthesia 2019