- Visão geral
- Características
- Applications
- Acessórios
- Documentos
-
DPTE®-FLEX Alpha Port
Maximum protection with minimum human intervention
- Enhance Aseptic Transfer with gloveless process
- Support for Annex 1 guidelines
- Easy to use
- Improve efficiency and ergonomics
- Optional features for enhanced functionality
- Seamlessly replaces the DPTE®-XS or any similar RTP with a 190mm diameter
Flexibility within aseptic transfer
Our DPTE®-FLEX transfer system improves the process by offering gloveless transfer, ensuring product sterility and integrity while minimizing the risk of contamination. With support for Annex 1 guidelines, it aligns seamlessly with regulatory requirements, showcasing your dedication to quality and compliance. The DPTE®-FLEX enhances efficiency and ergonomics to boost productivity and operator comfort. Supporting versatile applications—from liquids to components, petri plates to waste, etc.— our rapid transfer port adapts to your specific needs, providing unmatched flexibility. Plus, with optional features like a configurable funnel for optimized component transfer, you can customize the DPTE®-FLEX to tailor it precisely to your requirements.
Experience enhanced aseptic transfer, improved efficiency, and versatility—all with DPTE®-FLEX.
Discover gloveless aseptic transfer
Watch the full video and discover how the DPTE®-FLEX with its external handles eliminates the use of gloves for opening and thus reduces human intervention in the barrier system.
DPTE® Emergency Glove Ø190
Intervene on your line for emergency or maintenance. This emergency glove, connected to your line’s DPTE® Alpha port:
- enables quick intervention without stopping production, saving valuable time, minimizing production downtime, and reducing related costs.
- allows operators to address issues promptly, preventing product contamination or quality deviations.
- is a proactive solution demonstrating your commitment to quality and safety standards by empowering operators to address emergencies swiftly.
- is a maintenance-free solution that requires no in-house testing or bio-decontamination to save time and reduce the use of chemicals.
- is delivered sterile, ready-to-use, and integrity-tested by our team before delivery.
- seamlessly integrates existing production processes without requiring modifications or downtime for installation.
Related products
Safety at first
The core of the DPTE® system is the Alpha port with its secure interlock enabling totally safe connections and disconnections:
- The operator cannot open the DPTE® Alpha door when the DPTE® Beta part is not properly connected
- The operator cannot disconnect the DPTE® Beta part if the double door is not closed
- The operator cannot open the DPTE® Alpha door when the DPTE® Beta port is not equipped with the Beta part
External opening
The external handles of the DPTE®-FLEX, which perform the double functions (unlocking/locking and opening/closing), are fully accessible from outside the enclosure.
The Alpha door cannot move unless the external handle is actioned. The fully controlled Alpha door movement offers a safe opening, especially on an inclined wall.
In addition to its external opening, the DPTE®-FLEX can also offer internal opening as an option.
Dismountable funnel
To meet specific needs and to facilitate component transfer, we offer a long and a short funnel as an option. The funnel protects the alpha/beta seals and its patented FAST system (Funnel Add-on for Smooth Transfer) allows efficient component transfer to the process area (feeder/bowl).
The funnel is mounted on the isolator wall, above the DPTE® door and its position is controlled using a handle accessible from outside the enclosure. The dismountable funnel can be easily, safely, and quickly released with one hand, and the assembly is fully autoclavable.
Manual and externally openable DPTE®-FLEX Alpha Port
Manual and externally openable DPTE®-FLEX Alpha Port
Supporting the need for gloveless processes
Getinge has developed a sleeveless DPTE-BetaBag® reducing human intervention in the aseptic environment. The sleeve has been removed and its protective functions are now replaced by the funnel.
The DPTE®-FLEX with sleeveless DPTE-BetaBag is a fully validated and interlocked system. Together with the dismountable funnel, it offers a total transfer solution from the outside of the aseptic filling area to the processing area.
Sleeveless DPTE-BetaBag
Beta and alpha ports join to form a single validated unit when connected by rotation. The FDA-compliant silicone lip seals form a secure connection, allowing the door to be safely opened without breaking sterility or containment. The manually connected sleeveless DPTE-BetaBag comes in RTS (Ready to Sterilize) or RTU (Ready to Use) depending on the bag material for minimum human intervention, increased efficiency, simplified component transfer, and reduced risk of contamination.
Suitable for various applications within aseptic transfer
Validated to comply with international regulations, the DPTE® System
is used in various applications in aseptic and contained production.
Liquid Transfer
Component Transfer
Environmental Monitoring
Machine Parts
Waste Disposal
And many more...
Marketing Sales - Brochures
-
The original Rapid Transfer Port